Safety Gas Timer MT – MTS 59
Safety Gas Timer MT – MTS 59
Technical data sheet
Timers applications list
Timer model:
• Safety Gas MT – MTS 59
Switch gas on/off safety stop with or without acoustic signal.
ADVANTAGES:
1. Increased safety: switch gas off at the end of the running times to prevent any accident caused by fire.
2. Safe gas timer controls and turns off the gas on, allowing you more free time.
3. Electrcity: no power failure problem.
Standard features | MT – MTS 59 |
1. running times | 30′ – 45′ – 60′ – 90′ – 100′ – 120′ |
2. number of poles | on request: 1 or 2 poles |
3. OPTIONAL | switching wheel setting “continuously ON” or “continuously OFF” as desired |
4. acoustic signal | Gong: optional |
5. operating temperature | T 125ºC |
6. shaft diameter | 5 – 6 – 7 mm |
7. shaft length | on request |
8. shaft milling | on request |
9. shaft position | on request |
10. dimensions (mm) with acoustic signal |
43 x 58.5 x 52 |
11. dimensions (mm) without acoustic signal |
43 x 58.5 x 33.6 |
12. life cycles | 10.000 |
13. AQL | 0,65 |
14. accuracy | ±3% |
15. load current | 10(2)A 400Vac T 125ºC ENEC 03 16(3)A 250Vac T 125ºC ENEC 03 13(2)A 250Vac T 110ºC UL-CSA 15(2)A 120 Vac T 110ºC UL 15(4)A 120 Vac T 85ºC UL |
16. microswitch operating rate |
|
17. microswitch electric life |
|
18. conformity with | EN 60730-2-1 |
19. APPROVALS | ENEC 03 – UL |
• Gas cookers
• Gas ovens
• Hobs